Thermostatic Water Baths
Uses:
Evaporating, drying, concentrating and thermostatically heating. Widely adopted in medical and research units, factories, universities, chemical dyeing and petroleum
Characteristics:
1. It adopts new design structure, which could avoid the leakage of steam.
2. There are pointer type temperature controller and intellectual type temperature controller for selecting. The intellectual temperature controller has high lightness digital display and touch operating button, which is easy to operate. It has high precision on controlling the temperature.
3. Stainless steel workroom and upper cover
Main parameters:
Classification Specifications |
1 hole |
1 row & 2 holes |
1 row & 4 holes |
1 row & 6 holes |
2 rows & 4 holes |
2 rows & 6 holes |
2 rows & 8 holes |
Model |
DK-98-IIA |
√ |
√ |
√ |
√ |
√ |
√ |
√ |
Heating Mode |
Nature water convection heat transfer |
Function |
Temp. Range |
RT+5~100ºC |
Temp. Resolution Ratio |
0.1ºC |
Temp. Motion |
±0.5ºC |
Temp. Uniformity |
±1.0ºC |
Structure |
Inner Chamber |
Stainless steel |
Outer Shell |
Cold - rolled steel plate, resistance to chemical reagents coating on the surface |
Heater |
Stainless steel heating tube |
Power Rating |
0.4kW |
0.5kW |
1.0kW |
1.5kW |
1.0kW |
1.5kW |
2.0kW |
Controller |
Temp. Control Mode |
PID |
Temp. Setting Mode |
Touch button setting |
Temp. Display Mode |
Measuring temperature displays on the three digital tubes upper row, set temperature displays on the lower row |
Timer |
0~9999 min(with timing wait function) |
Operation Function |
Fixed temperature operation, timing function, auto stop. |
Program Mode |
Optional |
Additional Function |
Deviation Correction, menu key locked, power failure back-up, power-off memory |
Sensor |
CU50 |
Safety Device |
Over - rise alarm |
Specification |
Inner Chamber size(W*L*H)(mm)) |
168*168*120 |
325*168*120 |
653*168*120 |
945*168*120 |
325*325*120 |
480*325*120 |
635*325*120 |
Exterior size (W*L*H)(mm) |
355*240*190 |
510*240*190 |
820*240*190 |
1130*240*215 |
515*380*190 |
670*380*190 |
825*380*190 |
Packing size (W*L*H)(mm) |
405*320*235 |
555*320*235 |
870*320*235 |
1170*320*235 |
550*480*235 |
720*480*235 |
870*480*235 |
Volume |
3.4L |
6.6L |
13.2L |
19.1L |
12.7L |
18.7L |
24.8L |
Load per rack |
5kg |
Shelf Number |
1 |
Power Supply(50/60Hz)Current rating |
AC220V/1.8A |
AC220V/2.3A |
AC220V/4.5A |
AC220V/6.8A |
AC220V/4.5A |
AC220V/6.8A |
AC220V/9.1A |
NW/GW (kg) |
3.5/4 |
4.5/5 |
7/8 |
9/10 |
7/8 |
8/9.5 |
9.5/11 |
Optional Accessories |
Shelf, RS485 interface, Recorder, External Communication |
Remarks |
DK-98-II: Single row of digital tube time scale meter, it does not have PID and alarm function. |